top of page
Homebanner-IPPM.png

Intelligent Power Meter

IPP series is a single/three phase remotely monitored power meter, built-in 12 independent measurement modules. User may select any one phase of the input voltage as a measurement reference. It supports the monitoring of twelve loops of 1P2W, or four loops of 3P3W/3P4W, or a hybrid combination, providing flexible application.Each built-in power measurement module supports to monitor voltage, current, power, power factor, kWh and other information in real time. All information can be displayed sequentially on LED monitor by manual and communicated with monitoring device via web browser. SNMP utility is free bundled in the IPP series.IPP series built-in three groups isolated PT and 12 sets of removable external isolated CT, supports the most secure way to indirectly measure branches of power information in the power distribution panel. IPP series is small and may be easily surface mounted on anywhere you prefer.IPP-S series combine power and environment monitoring with remote relay control. Its output relays can be triggered manually, or tied to specific alarm settings, includes the temp./humidity sensor and four digital inputs.

Features

(Functions vary by model)

Cost saving for software installation

IPP series provides free central management utility to monitor group of IPP series, saving a lot time and cost to build up management system.

Dedicated Loops Measurement

There are 12 built-in measurement modules. Each module with independent and complete power measurement capabilities, provides real time measurement data.

Full Range

The voltage range is 60V-440V (50 / 60Hz.); the current range is 0.5A-50A and maximum to 200A

High Precision

The accuracy rate of kWh measurement is within ±1.0% (@PF=1.0, Rated Current), and W, V, A, VA, PF within ±1.0% (@Rated Current).

Low power consumption

The power consumption of IPP series is less than 6W.

Calculation and Control for Power Demand

To avoid exceeding the amount of contracted electricity, IPP-S will notify the administrator via mail, TRAP in advance, or use the pre-setting DO condition to turn off the specified secondary electrical equipment, To provide a power demand curve, clearly shows the gap between real-time electricity consumption and contract volume.

Various method to manage power information

User may monitor power consumption on web, utility and APP.

Flexibility

12 measurement modules may be configured optionally as single-phase, three-phase power or a combination of hybrid.

High Resolution

Active power measurement shows 0.001kW-50kW; energy measurement displays 0.001kWh-99999kWh.

Remote Monitor

IPP series may remotely monitor power consumption Via TCP/IP and SNMP; it reads complete power information of each loop once a second.

DI/DO

It is built-in four digital inputs and four relay output ports. The relay outputs allow for automatic response by the alarm conditions you select. The relays can trigger flashing lights, back-up a/c (via contact) and/or other external devices. When the current and DI signal deviates from the preset conditions, it can trigger DO to control the power output.

Power Record

Through the web page shows the last 5000 power data. You can also check all the power history records stored on the SD card via FTP.

Hot line installation

IPP series provide CT clamps for installation on the monitored circuit. The installation could be executed under power-on status.IPP series provide CT clamps for installation on the monitored circuit. The installation could be executed under power-on status.

Multi-functions

Each loop may measure single and three-phase of the real time voltage (V), current (A), power (W), power factor (PF) and the totalization of kWh, kVARh, kVAh.

Safety

IPP series adopts U.S. high-precision industrial microprocessor with a ferroelectric memory (FRAM), being free from power outages and restriction of erase/write cycles. It is highly anti-noise and reliable on saving data.

Reliability

IPP series adopts indirect measurement through PT and CT, isolated from measurement device. After installation all wiring and terminals are protected by terminal cover. IPP series also grants FCC & CE EMC certification.

Cloud Monitor

Through the cloud to collect individual loop power information and 4 digital input status display. And control 4 sets of power output.

Modbus Communication

IPP-B supports Modbus, integrated industrial communication system

Model List
Single Circuit
Multiple Circuits
Intellignet power meter, IPP
IPP-M1-C00
1P2W/1P3W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

-

Data Sheet

Intellignet power meter, IPP
IPP-M3-C00
3P3W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

-

Data Sheet

Intellignet power meter, IPP
IPP-M4-C00
3P4W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

-

Data Sheet

Intellignet power meter, IPP
IPP-S1-C00
1P2W/1P3W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

4 built-in DIDO

Data Sheet

Intellignet power meter, IPP
IPP-S3-C00
3P3W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

4 built-in DIDO

Data Sheet

Intellignet power meter, IPP
IPP-S4-C00
3P4W

12 built-in CT, measure up to 200A

Advanced network features

(1) RJ45

USB to Wifi ready

(2) RJ11

4 built-in DIDO

Data Sheet

bottom of page